Corrosion inhibitor emulsified acids Corrosion inhibition additives
Product introduction
Technical Data
Appearance |
Dark red/ Brown Liquid |
Specific Gravity, 20℃ |
1.0-1.2 |
pH (neat) |
2.0-6.0 |
Soluble in water and acid |
Miscible |
Ionic Charge |
Cationic |
Flash point |
Beyond 50℃ |
Safety Precautions
Usage
Tempte |
15%HCL&12-3Mud |
20%HCL |
28%HCL |
<200℉ |
6 |
8 |
12 |
201-225℉ |
8 |
12 |
16 |
226-250℉ |
10 |
15 |
20 |
251-300℉ |
12-15 |
15-24 |
24-30 |
301-350℉ |
20-30 |
30-50 |
40-60 |
Concentration is dependent on acid type, strength, bottom-hole temperature, contact time, and additional additives.
Applications
■ Matrix acidizing stimulation operations
■ Fracture acidizing stimulation operations
■ Wellbore cleaning with acid formulations
Features and Benefits
■ Excellent high-temperature metal corrosion protection
■ Provide corrosion protection in all HCL and HCL-HF blends up to 177℃
■ Contains no heavy metal salts, and has a high flash point
■ Reduces acid corrosion rates on common oilfield tubulars, including coiled tubing
■ Improves design flexibility because it works in virtually all strengths of hydrochloric acid and mixtures of hydrochloric-hydrofluoric and hydrochloric-organic acids
■ Disperses easily in all acid-based fluids
■ Can provide acid corrosion inhibitor protection for as long as 24 hours
■ Can provide acid corrosion inhibitor protection for K55,J55, N80, CT80, QT800 and P110、P110S etcetera
Attachment
Test of specific gravity
1. Loading 250 ml sample into 250 ml measuring cylinder.
2. Place the measuring cylinder in a water bath and keep the temperature at 25℃.
3. Put in a densitometer to measure sample specific gravity, record it.
Test of pH value
1. Loading 100 ml sample into 250 ml beaker.
2. Place the beaker in a water bath and keep the temperature at 25℃.
3. Check the pH meter.
4. The pH value of the sample is measured by pH meter, record it.
Test methods of corrosion rate
1. Keep the oven temperature at 160℃.
2. Configure 200 ml of 20% HCL, adding predetermined amount of CI and INTENSIFIER.
3. Put prepared steel Coupons in the cell , seal, tighten, put in oven, preheat for 30 minutes at 160℃.
4. Start the timing and keep the Aging Cell for required exposure period in mechanical convection oven.
5. Take the cell out of the oven, cool, release the pressure, take out the metal coupon, clean, wash and weigh for any weight loss.
6. Calculate the corrosion rate in Lbs/Ft2 and g/(m2.h).
7. Check for any pitting on the metal surface and report.
description2