Acid corrosion inhibitor UZ CI-180V
Product introduction
HCl of any strength has an undesirable reaction on steel. The amount of damage will depend upon contact time, acid strength, and temperature conditions. Acid corrosion inhibitor can provide effective protection for steel in HCL. Common acid Corrosion Inhibitors are not compatible with visco-elastic surfactants. UZ CI-180V is specially developed for visco-elastic surfactant diverting acid system. UZ CI-180V is well compatible with most viscoelastic surfactants.
Technical Data
Appearance |
Light yellow to brown liquid |
Density, g/cm3 |
1.0-1.2 |
pH (1%) |
2.0-6.0 |
Solubility |
Soluble in water and acid |
Innic Charge |
Cationic |
Flash Point |
Beyond 60℃ |
Applications
Matrix acidizing stimulation operations
Fracture acidizing stimulation operations
Wellbore cleaning with acid formulations
Features and Benefits
1.Excellent high-temperature metal corrosion protection
2.Provide corrosion protection in all HCL and HCL-HF blends up to 330F/165℃
3.Contains no heavy metal salts, and has a high flash point
4.Reduces acid corrosion rates on common oilfield tubulars, including coiled tubing
5.Improves design flexibility because it works in virtually all strengths of hydrochloric acid and mixtures of hydrochloric-hydrofluoric and hydrochloric-organic acids
6.Disperses easily in all acid-based fluids
7.Can provide acid corrosion inhibitor protection for as long as 24 hours
8.Can provide acid corrosion inhibitor protection for K55,J55, N80, CT80,C-95, QT800 and P110、P110S etcetera .
parameter
15% DIVERTING ACID | |||||
Fluid NO. |
1 |
2 |
3 |
4 |
|
Temperature(F) |
194F |
240F |
280F |
300F |
|
Acid Concentration |
15% |
15% |
15% |
15% |
|
Additive Code |
Description |
GPT/PPT |
GPT/PPT |
GPT/PPT |
GPT/PPT |
CII-400 |
Corrosion Inhibitor Intensifier |
0 |
0 |
40 |
40 |
BA2-01VES |
Corrosion Inhibitor |
8 |
10 |
15 |
18 |
IC-150 |
Iron Chelating Agent |
20 |
20 |
20 |
20 |
HS-40 |
H2S Scavenger |
5 |
5 |
5 |
5 |
VES2-11 |
Diverting Surfactant |
40 |
60 |
75 |
80 |
Corrosion rate for hrs(lb/ft2) |
0.0121 |
0.0117 |
0.0121 |
0.0248 |
|
Pitting Index≤1 |
0 |
0 |
0 |
0 |
|
|
|
|
|
|
|
20% DIVERTING ACID | |||||
Fluid NO. |
1 |
2 |
3 |
4 |
|
Temperature(F) |
194F |
240F |
280F |
300F |
|
Acid Concentration |
20% |
20% |
20% |
20% |
|
Additive Code |
Description |
GPT/PPT |
GPT/PPT |
GPT/PPT |
GPT/PPT |
CII-400 |
Corrosion Inhibitor Intensifier |
0 |
0 |
40 |
40 |
BA2-01VES |
Corrosion Inhibitor |
8 |
10 |
15 |
18 |
IC-150 |
Iron Chelating Agent |
20 |
20 |
20 |
20 |
HS-40 |
H2S Scavenger |
5 |
5 |
5 |
5 |
VES2-11 |
Diverting Surfactant |
40 |
60 |
75 |
80 |
Corrosion rate for hrs(lb/ft2) |
0.0155 |
0.0141 |
0.0185 |
0.0382 |
|
Pitting Index≤1 |
0 |
0 |
0 |
0 |
Safety Precautions
Packaging and Storage
Packed in 200Litre drum or 1000 Litre IBC (Tote Tank).
Store in dry, well-ventilated area. Keep container closed. Keep away from heat, sparks and flames. Store away from incompatibles. Follow safe warehousing practices regarding palletizing, banding, shrink-wrapping and /or stacking.
Attachment
Test of specific gravity.
Loading 250 ml sample into 250 ml measuring cylinder.
Place the measuring cylinder in a water bath and keep the temperature at 25℃.
Put in a densitometer to measure sample specific gravity, record it.
Test of pH value.
Loading 100 ml sample into 250 ml beaker.
Place the beaker in a water bath and keep the temperature at 25℃.
Check the pH meter.
The pH value of the sample is measured by pH meter, record it.
Test methods of corrosion rate.
Preparation of desired concentration HCl acidizing fluid.
The acid solution was prepared as acidizing fluid recipe.
The prepared 200 ml of the desired concentration HCl acidizing fluid was poured into the liner respectively.
Immersed the pre-weighed and measured two coupons into the acid solution.
Put the liner into the corrosion reactor and covered lid.
Warmed up the corrosion reactor to desired temperature, then kept reaction for desired hours.
Released pressure and opened lid, took out the liner from the corrosion reactor, then took out the coupons from the liner, wiped, cleaned and weighed.
Calculated the corrosion rate at different time, the unit is Lbs/Ft2.
Checked if the coupon was with corrosive pitting; if yes, record it.
Physical Indicators of UZ CI-180V
ITEMS |
Specifications |
RESULTS |
pH @ 25 ℃ |
pH≤6 ( pH meter) |
0.84 |
S.G. @ 25 ℃ |
1.0-1.2 ( Densimeter) |
1.112 |
CORR RATE |
≤0.05Lbs/ft2(C-95,20% HCl+8%Acid diverter (UZV-180)+ 1.8%Corrosion inhibitors (UZ CI-180V)+1% |
0.0261Lbs/ft2 |
description2